OUR PRODUCTS

Oil & Petroleum Testing Eqipments

SSI-401

Abel's Flash Point Apparatus 'U-TECH'

Suitable for determination of close cup flash point of petroleum and petroleum products having flash points below 70°C. Designed as per IP-33, IP-170 and IS 1448 (Part i) 1985 (P: 20). Supplied with oil cup, cover fitted with stirrer, thermometer socket, waterbath and stand, electric heater is fitted at bottom workable at 220 Volts AC. supply. Supplied with one thermometer. Temperature is controlled through a energy regularfitted to the unit.

Optional Accessories

  • Electrically driver stirrer with a FHP motor having flexible shaft.
  • Spare oil cup thermometer (-35°C to 70°C)IP-74C
  • Water bath thermometer (-30°C to 80°C) IP-75 C


SSI-402

Pensky Marten Flash Point Apparatus 'U-TECH'

Designed as per IP-34, ASTMD-93 and IS 1448 (Part i) and IS 1209-1953 method B. It is use for determination of close cup flash points of fuel, oils, other viscous material and suspension of solids. Useful for both low range as well as high range flash points of samples useing different thermometers IP-15C or IP-16C respectively. The cover with spring operated rotating Shutter having Oil Test Jet Flame Device, stirrer with flexible shaft. The Assembly rests in Air Bath which is covered with Dome shape metal top. The cup is fitted with insulated Handle and locking arrangement near Cup flange. The assembly energy regulator. Suitable to work on 220 volts AC supply. Supplied with one thermometer.

Optional Accessories

  • Electrically driver stirrer with a FHP motor having flexible shaft.
  • Spare IR-15C thermometer LOW RANGE (-70°C to 110°C)
  • Spare IP-16C thermometer HIGH RANGE (-90°C to 370°C)


SSI-403

Cleaveland Flash And Fire Point Apparatus 'U-TECH'

Designed as per IP-36 and IS : 1448 (P : 69) for determination of flash point and fire point of petroleum products except fuel oil having open cup flash below 80°C. It consists of a open cup, heating plate, thermometer clip and test flame attachment with swivel joint for passing oven test liquid surface. Heating is controlled by means of energy regulator. To work on 220 volts AC supply. Supplied with one thermometer


    Optional accessories

  • Spare thermometer IP-28C(-5°C to 400°C)


SSI-404

Red Wood Visometer 'U-TECH'

Designed as per IP-70 for viscosily tests petroleum products. Two adaptatons of Redwood Viscometers are available. Redwood N0.1 is suitable for liquids having redwood flow between 20 to 2000 seconds. Redwood NO. 2 are suitable for liquids heaving redwood flow exceeding 2000 seconds. The unit has a electrically heated bath with energy regulator for temperature control. Supplied complete with a tap, oil cup, precision jet, cup cover, ball value, thermometer clip, stirrer and M S. stand with leveling screws. Supplied with one thermometer.


    Optional accessories

  • Electrically driven stirrer with a FHP motor having flexible shaft
  • Spare thermometer LOW RANGE IP-8C(0°C to 45°C)
  • Spare thermometerMEDIUM RANGE IP-9C(40°Cto85°C)
  • Spare thermometer HIGH RANGE IP-8C(76°C to 122°C)
  • Stop Watch (1/10" of sec.)


SSI-405

Penetrometer 'U-TECH'

As per IP 49,50 & 167 specifications and also as per IS 1448 (P: 92) & (P :93). This apparatus is used for penetration test on a wide variety of materials such as greases, petroleum, bitumen, tar, wax, polish, food stuff, rubber asphalts and pharmaceutical creams. A given force is applied over a given period of times and the depression is made in the Sample which is measured in tenths of a head Support mounted on a vertical rod which can be adjusted for height. A rack and pinion and pointer assembly provides fine adjustment of needle tip to Sample and in Corporates a Slipping clutch mechanism which make reading of penetration and subsequent resetting a sample and accurate operation. The dial graduate from 0-400 in one tenth millimeter Sub Division. The Instrument is supplied with two sample containers.

  • Penetrometer Apparatus with containers and weights having peneteration Needle.
  • Penetrometer Apparatus with containers and weights having PENETERATION CONE hollow type.
  • Penetrometer Apparatus with ELECTRONIC DIGITAL TIMER & electrical arrangement with Brass Cone & Needle